Latest and effective Cisco CCNP Data Center 300-180 Certification Exam Questions, 300-180 dumps | 100% Free

Get the Cisco CCNP Data Center 300-180 Certification Exam. “Troubleshooting Cisco Data Center Infrastructure (DCIT)”: https://www.pass4itsure.com/300-180.html (Q&As: 452). Free Cisco CCNP Data Center 300-180 exam practice test. Improve your skills and exam experience!

Get the latest Cisco CCNP Data Center 300-180 pdf

[PDF] Free Cisco 300-180 pdf dumps download from Google Drive: https://drive.google.com/open?id=1M3kdgxChjiRczABkDLb7HJqTmUHKI8Vd

Related Cisco CCNP Data Center Exam pdf

Valid information provided by Cisco officials

300-180 DCIT – Cisco: https://www.cisco.com/c/en/us/training-events/training-certifications/exams/current-list/dcit.html

The latest Cisco CCNP Data Center 300-180 exam practice questions test your strength

QUESTION 1

Which three send and receive locations an administrator can find the root cause for a network issue on the Cisco UCS

domain? (Choose three.) 

A. between fabric interconnect and LAN or SAN 

B. between the FEX and fabric interconnect 

C. between each FEX on the Cisco UCS chassis 

D. between the host and FEX 

E. between fabric interconnects within the domain 

F. between the Cisco UCS chassis and system interconnects 

Correct Answer: ABD 

 

QUESTION 2

If a server is not associated with a service profile, the activated firmware remains pending. Which two steps should you

take? (Choose two.) 

A. Manually reboot the server. 

B. Reset the server to a new profile. 

C. Reset the unassociated server to activate the firmware. 

D. Reinitialize the firmware process with Cisco UCS Manager. 

E. Download the firmware and start over. 

F. Shut down gracefully and start over. 

Correct Answer: AC 

 

QUESTION 3

Refer to the exhibit.pass4itsure 300-180 exam question q3

You configure a vPC between two Cisco Nexus 7000 Series switches but the peer link will not come up. What is the
problem?
A. The system priority must be the same.
B. The configuration is correct. The problem lies elsewhere.
C. The role priority must be the same.
D. The vPC domain numbers must be different.
Correct Answer: B

 

QUESTION 4
Which method does Cisco recommend for recovering a fabric interconnect when you have no working images on the
bootflash?
A. Reboot the primary fabric interconnect.
B. Receive the kickstart image by using TFTP.
C. Download the system image.
D. Initiate auto-install.
Correct Answer: B
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ts/guide/UCSTroubleshooting/UCSTroubleshooting_chapter_01010.pdf


QUESTION 5
You have an unresponsive blade server. You suspect that there is an issue with the current firmware. Which action do
you take to reboot the server from the Cisco UCS Manager GUI?
A. Reset the server.
B. Reset CIMC.
C. Reset BMC.
D. Recover the corrupt BIOS.
Correct Answer: B

 

QUESTION 6
The installation of a new OTV network connecting two data centers via a service provider LAN has failed verification
steps. Which statement explains why certain types of data are not being successfully transferred across the OTV
network?
A. The number of extended VLANs across all configured overlays may be greater than 256.
B. The number of MAC addresses on either edge device may exceed 4000.
C. The additional 42-byte OTV overhead, along with the DF bit being set, may cause the service provider to drop
packets based on their 1500 MTU settings.
D. Having more than two edge devices per site is not supported.
Correct Answer: C

 

QUESTION 7
Refer to the exhibit.pass4itsure 300-180 exam question q7

In the initial SAN deployment or after topology changes in the SAN, some hosts cannot communicate with storage.
What are three possible causes of the problem? (Choose three.)
A. misconfigured fabric timers
B. misconfigured port parameters
C. VSAN pruning
D. VSAN trunking issues
E. VLAN problems
F. mismatched zoning
Correct Answer: ABF

 

QUESTION 8
You use dynamic vNICs. You create a new service profile. You receive an error message that indicates that you
exceeded the number of dynamic vNICs. Which two components can affect the maximum number of dynamic vNICs in
the Cisco UCS environment? (Choose two.)
A. the model of the fabric interconnects
B. the number of chassis uplinks
C. the model of the FEX
D. VMDirectPath sizing
Correct Answer: AB

 

QUESTION 9
Refer to the exhibit.

pass4itsure 300-180 exam question q9

You see the fault when configuring a global ID pool in Cisco UCS Central. Which scenario could cause the issue?
A. The same ID is defined in Cisco UCS Central and Cisco UCS Manager.
B. Global service profiles consume IDs from the blocks that have an assigned ID range qualifier.
C. The same IP address is configured in two registered domains.
D. The same ID is assigned to the service profiles in two registered domains.
Correct Answer: D

 

QUESTION 10
In a Cisco UCS environment, what are the three power types in a power policy? (Choose three.)
A. backup
B. grid
C. redund
D. n-plus-1
E. non-redund
F. plus-1
Correct Answer: BDE

 

QUESTION 11
Refer to the exhibit.pass4itsure 300-180 exam question q11

The two switches are stuck in the EXCHANGE and EXSTART states. Which option is a possible cause of the issue?
A. The subnet mask is mismatched.
B. The interfaces are not connected.
C. The MTU is mismatched.
D. The IP address of the OSPF process is incorrect.
Correct Answer: C


QUESTION 12
What should you do when you see faults during the initial setup and discovery process?
A. Take note and address the faults.
B. You can safely ignore these faults.
C. Log them and try to address the first one.
D. Reboot until the error messages go away.
Correct Answer: B


QUESTION 13
A Cisco UCS chassis has two ports on I/O Module 1 connected to Fabric Interconnect A, and two ports on I/O Module 2
connected to Fabric Interconnect B. The I/O modules are connected to ports 1 and 2 on their respective fabric
interconnects, and end host mode is configured. After a link failure occurs on port 1 of I/O Module 1, what happens to
the traffic that was pinned to that link?
A. The traffic fails until the link issue is resolved.
B. The traffic is repinned to I/O Module 2 link 1, which is connected to Fabric Interconnect
C.
D. The traffic is repinned to the remaining link between I/O Module 1 and Fabric Interconnect A.
E. The traffic is repinned automatically to Fabric Interconnect B.
Correct Answer: C

Follow Pass4itsure free sharing of YouTube channels

We offer more ways to make it easier for everyone to learn, and YouTube is the best tool in the video. Follow channels: https://www.youtube.com/channel/UCTP5RClZrtMxtRkSvIag0DQ/videos get more useful exam content.

Share Pass4itsure coupons for free

pass4itsure coupon

Reasons to choose Pass4itsure

Pass4itsure offers the latest exam practice questions and answers free of charge! Update all exam questions throughout the year, with a number of professional exam experts! To make sure it works! Maximum pass rate, best value for money! Helps you pass the exam easily on your first attempt.

why pass4itsure

This maybe you’re interested

Summarize:

The latest Cisco CCNP Data Center 300-180 dumps, online 300-180 practice test questions,
pass 300-180 exam: https://www.pass4itsure.com/300-180.html (Q&As: 452).
Boost exam skills Share 300-180 pdf and 300-180 Youtube videos for free